- Lab water system
- Medical water system
- Industrial water system
|
With LCD controlling system, 3 way water quality sensor, cartridge replacing alarm, timing and quality dispensing, stainless steel shell, built-in 2 set pressure tanks, single stage RO system and 1 pump, Medium-S series ultrapure water system is superior choice of ultrapure water’s mass usage for high grade experiments.
With tap water inlet, its output ranges from 45 to 125 liters/hour. It can produce single stage RO water and ultrapure water. The single stage RO water’s ion rejection rate is more than 97%, and the ultrapure water’s resistivity absolutely reaches to 18.2MΩ.cm. It completely meets the highest grade I standard of ASTM, CAP, CLSI, EP and USP.
|
Flow Schematic

Specifications
Model |
Standard |
Eliminating endotoxin |
Low TOC |
Synthesizing |
Medium-S
300/400/600/800 |
Medium-S
300/400/600/800UF |
Medium-S
300/400/600/800UV |
Medium-S
300/400/600/800UVF |
Output(25°C)* |
300 series:45 liters/hour, 400 series:63 liters/hour,
600 series:94 liters/hour, 800 series:125 liters/hour |
Pure water outlet |
2: reverse osmosis water, ultrapure water |
Ultrapure water quality |
 |
Resistivity(25°C) |
18.2MΩ.cm |
TOC* |
<10ppb |
<10ppb |
<3ppb |
<3ppb |
Bacteria |
<0.01cfu/ml |
Particle(>0.2µm) |
<1/ml |
Endotoxin |
N/A |
<0.001Eu/ml |
N/A |
<0.001Eu/ml |
RNases |
N/A |
<1pg/ml |
N/A |
<1pg/ml |
DNases |
N/A |
<5pg/ml |
N/A |
<5pg/ml |
RO water quality |
 |
Ion rejection rate |
97%-99% (new RO membrane) |
Organic rejection rate |
>99%, when MW>200 Dalton |
Particles and bacteria rejection rate |
>99% |
Feed water requirements |
Tap water, temperature:5-45°C,pressure:1.0-4.0Kgf/cm2 |
Dimension and weight |
Length×Width×Height:640×540×1110mm / Weight: about 70Kg |
Electrical requirements |
AC110-240V, 50/60Hz |
Power |
300/400 series:120W, 600/800 series: 240W, |
Standard configuration |
Main body (Including 1 set of cartridge)+2 set built-in 15 liters pressure tank |
Remarks:
*The value will be influenced by temperature and feed water’s quality.
Cartridges |
Item no. |
Commodity |
Approximate replacement term /set |
PC-20PP |
20" spun fiber cartridge |
2-6 months |
PC-20AC-G |
20" granular active carbon cartridge |
2-6 months |
PC-20AC-B |
20" active carbon block cartridge |
2-6 months |
RO-150GPD |
150 GPD reverse osmosis membrane |
12-24 months |
RO-200GPD |
200 GPD reverse osmosis membrane |
12-24 months |
RO-300GPD |
300 GPD reverse osmosis membrane |
12-24 months |
RO-400GPD |
400 GPD reverse osmosis membrane |
12-24 months |
RO-600GPD |
600 GPD reverse osmosis membrane |
12-24 months |
PTC-AC-HZB1 |
Reducing TOC cartridge |
9000 liters pure water |
PTC-MBR-12L |
12l mixed bed resin cartridge |
20000 liters pure water |
PTC-UPPR-12L |
12l ultrapure polishing resin cartridge |
20000 liters pure water |
PTC-MBR-25L |
25l mixed bed resin cartridge |
40000 liters pure water |
PTC-UPPR-25L |
25l ultrapure polishing resin cartridge |
40000 liters pure water |
PTC-UPPR-M |
Ultrapure polishing resin cartridge |
1000 liters pure water/set |
TF-0.2µm-B |
0.2µm terminal filter |
- |
UF-5000D |
MWCO5000D UF cartridge |
- |
LAMP-(185nm&254nm)-10W-M |
Double wavelength(185&254)nm uv lamp |
9000 hours |
|